Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2026-09-17 Pk Agenda Packet
1685 CROSSTOWN BOULEVARD N.W. • ANDOVER, MINNESOTA 55304 • (763) 755-5100 FAX (763) 755-8923 • WWW.ANDOVERMN.GOV Park & Recreation Commission Regular Meeting Thursday, September 17, 2026 City Hall – Council Chambers 1. Call to Order – 6:00 p.m. 2. Resident Forum 3. Agenda Approval 4. Approval of Minutes (7/16/26) 5. Discuss Pine Hills North Garage Construction 6. Discuss Tree Lighting Event 7. Outstanding Items 8. Chair’s Report 9. Adjournment STAFF REPORT Agenda Item #4 1 TO: Park & Recreation Commission FROM : David D. Berkowitz, Director of Public Works/City Engineer SUBJECT: Approval of Minutes DATE: September 17, 2026 INTRODUCTION The following minutes were provided by TimeSaver, reviewed by Management Staff, and submitted for Park & Recreation Commission approval: July 16, 2026 Regular Meeting BACKGROUND The minutes are attached for your review. ACTION REQUESTED The Park & Recreation Commission is requested to approve the above minutes. Attachment: 07/16/26 Regular Meeting Minutes 1 PARK AND RECREATION COMMISSION MEETING – JULY 16, 2026 2 MINUTES 3 4 The Regular Meeting of the Andover Park and Recreation Commission was called to order 5 by Chair Johnson on July 16, 2026, 6:00 p.m., at the Andover City Hall, 1885 Crosstown 6 Boulevard NW, Andover, Minnesota. 7 8 9 Commissioners Present: Chair Bruckner Johnson, Commissioners Emily Honer, 10 Kristin Lackie, Liza Shafto, and Liliya Ustimchuk 11 12 Commissioners Absent: Shane Stenzel and Jim Lindahl 13 14 Also Present: City Planner Peter Hellegers 15 16 RESIDENT FORUM. 17 18 No one appeared to address the Commission. 19 20 AGENDA APPROVAL. 21 22 Commissioner Lackie requested an item be added to the agenda for the discussion of the 23 potential cell tower in Timber Trails Park. 24 25 Motion by Commissioner Lackie, seconded by Commissioner Honer, to approve the 26 agenda, adding an item for discussion of the potential cell tower in Timber Trails Park, for 27 the July 16, 2026, Park & Recreation Commission Regular Meeting as amended. Motion 28 carried on a 5-ayes, 0-nays. 29 30 APPROVAL OF MINUTES. 31 32 May 21, 2026, Park & Recreation Commission Regular Meeting 33 34 Motion by Commissioner Honer, seconded by Commissioner Shafto, to approve May 21, 35 2026, Park & Recreation Commission Regular Meeting Minutes as presented. Motion 36 carried on a 5-ayes, 0-nays. 37 38 WARD LAKE PRESERVE PRELIMINARY PLAT REVIEW 39 40 Chair Johnson disclosed a conflict of interest regarding the proposed Ward Lake Preserve 41 Development and formally recused himself from the discussion and recommendation. 42 43 City Planner Peter Hellegers explained that the proposed subdivision is essentially 44 unchanged from the sketch plan the Commission reviewed earlier in the year. Since then, 45 Andover Park & Recreation Commission Regular Meeting Minutes – July 16, 2026 Page 2 the applicant has begun the preliminary plat process, but the overall layout remains the 1 same. 2 3 Mr. Hellegers said the proposal includes a nine-lot rural residential subdivision on 4 approximately 31 acres south of Ward Lake. He reviewed the site plan, highlighting the 5 proposed roadway, surrounding wetlands, and residential lots. He also explained that no 6 park land dedication is proposed because the City's Park Dedication Study does not identify 7 the need for additional parks in the area. However, the City Code requires the Park and 8 Recreation Commission to review the preliminary plat and recommend on the park 9 dedication requirements. 10 11 Motion by Commissioner Lackie, seconded by Commissioner Shafto, to recommend cash 12 in lieu of land for the Ward Lake Preserve Plat. Motion carried on a 4-ayes, 0-nays. 13 14 Chair Johnson returned to the meeting. 15 16 COMPREHENSIVE PLAN STEERING COMMITTEE 17 18 Mr. Hellegers presented an overview of the City's upcoming 2050 Comprehensive Plan 19 Update, explaining that metropolitan cities are required to update their comprehensive 20 plans every ten years. He said the City Council plans to establish a steering committee with 21 representatives from each advisory commission to help review the plan throughout the 22 process. The committee will review topics including parks and recreation, land use, 23 transportation, housing, utilities, and other issues affecting the City's long-term growth. He 24 added that meetings are expected to be held on the fourth Tuesday of each month, 25 beginning around 7:00 p.m., although the schedule has not yet been finalized. 26 27 Chair Johnson asked how long membership on the steering committee would last. Mr. 28 Hellegers responded that the exact duration depended on the pace of the planning process. 29 He explained that the Metropolitan Council currently requires local comprehensive plans 30 to be completed by the end of 2028, unless an extension is granted. Although the steering 31 committee would likely meet over an extended period, meetings would occur only as 32 necessary, and Commissioners would receive meeting notices, agendas, and background 33 materials in advance of each session. 34 35 Chair Johnson then invited Commissioners to volunteer for the appointment. 36 37 Commissioners Shafto and Lackie both volunteered for the steering committee, but 38 Commissioner Lackie deferred the appointment to Commissioner Shafto. 39 40 Motion by Commissioner Lackie, seconded by Commissioner Honer, to appoint 41 Commissioner Shafto to represent the Parks and Recreation Commission on the 2050 42 Comprehensive Plan Steering Committee. Motion carried on a 5-ayes, 0-nays. 43 44 DISCUSS POTENTIAL CELL TOWER IN TIMBER TRAILS PARK 45 Andover Park & Recreation Commission Regular Meeting Minutes – July 16, 2026 Page 3 1 City Planner Peter Hellegers explained that the discussion was for informational purposes 2 only and that no formal application had been submitted. He said the City had received an 3 inquiry from a potential applicant seeking feedback on whether Timber Trails Park would 4 be an appropriate location for a future cellular tower before moving forward with a formal 5 proposal. He reviewed three potential tower locations within the park, noting that two of 6 the sites near the park’s corners could have reduced setback concerns while minimizing 7 impacts on the athletic fields, and reminded the Commission that it had previously 8 discussed a similar request involving Fox Meadows Park. 9 10 The Commission discussed the three potential tower locations within Timber Trails Park, 11 with Commissioners generally agreeing that the northeast and southeast corner locations 12 would have less impact on park activities than placing a tower between the athletic fields. 13 14 Mr. Hellegers said staff reached the same conclusion and noted that the southeast corner 15 appeared to be the preferred location because it could use existing trail access for 16 maintenance and would be less likely to interfere with any potential field expansion 17 within the park. He explained that communication towers are allowed up to 120 feet in 18 height, subject to the conditional use permit process, and that any proposal would 19 undergo public review with mailed notices to nearby property owners. 20 21 Chair Johnson asked about maintenance access. Mr. Hellegers explained tower 22 maintenance is infrequent, and the existing trail would likely provide adequate access. 23 24 Commissioner Honer asked whether the tower would accommodate multiple wireless 25 providers. Mr. Hellegers explained that no final design had been selected. Still, previous 26 City Council directions have favored a shared tower that can serve multiple carriers 27 rather than constructing several separate towers throughout the City. 28 29 The Commission also discussed the size of the proposed lease area, potential impacts on 30 neighboring homes, and the public review process. 31 32 Mr. Hellegers explained that surrounding homes are set back a considerable distance 33 from the proposed location and that any future application would require a conditional 34 use permit, public hearing, and final City Council approval. 35 36 Commissioner Shafto suggested that if a tower is ultimately approved, lease revenue 37 should initially be used for improvements at Timber Trails Park before being used to 38 support projects throughout the City's park system. 39 40 Commissioner Lackie supported that concept and said the southeast corner appeared to 41 provide the best balance between improving cellular service while minimizing impacts on 42 nearby residents and future park development. 43 44 Andover Park & Recreation Commission Regular Meeting Minutes – July 16, 2026 Page 4 Commissioner Honer also supported the southeast location because it would preserve 1 opportunities for future expansion of athletic fields. 2 3 Mr. Hellegers concluded that staff had received the Commission's feedback and would 4 share its preference for the southeast corner with the interested party. He noted that if the 5 applicant decides to move forward, the proposal will return to the City's normal land use 6 review process, including public hearings, before the City Council makes a final decision. 7 8 9 CHAIR’S REPORT 10 11 Park Maintenance 12 13 Commissioner Honer complimented Parks staff for their prompt maintenance work at 14 Sunshine Park after noticing that weeds around the entrance sign had been removed and 15 fresh mulch installed. She said the improvements made the entrance look well maintained 16 and appreciated the quick response. 17 18 Commissioner Reports 19 20 Commissioner Shafto recognized the success of this year's Andover Family Fun Fest, 21 thanking the many volunteers, City staff, and organizations that helped organize the event. 22 The Commissioner said their family attended and enjoyed the festival, noting that it has 23 become a favorite annual community event. The Commissioner also expressed 24 appreciation for everyone who worked behind the scenes to make the event successful. The 25 remaining Commissioners reported no additional updates. 26 27 ADJOURNMENT. 28 29 Motion by Commissioner Honer, seconded by Commissioner Shafto, to adjourn the 30 meeting at 6:22 p.m. Motion carried on a 5-ayes, 0-nays. 31 32 33 Respectfully Submitted, 34 35 Sue Osbeck, Recording Secretary 36 TimeSaver Off Site Secretarial, Inc. 37 STAFF REPORT Agenda Item #5 1 TO: Park and Recreation Commission FROM : David D. Berkowitz, Director of Public Works/City Engineer SUBJECT: Discuss Pine Hills North Garage Construction DATE: September 17, 2026 INTRODUCTION The Park & Recreation Commission is requested to discuss the proposed Pine Hills North Garage Construction. BACKGROUND A storage garage was identified to be constructed at Pine Hills North when the original master plan for the complex was developed in 2013 in which the soccer association was going to build at some time. Boreal FC soccer has the funds to construct the garage this fall. The draft construction plans, and a siding picture are attached for your information along with the proposed garage location, construction cost estimate for the garage and the Pine Hills North 2013 master Plan. As this garage is to be placed on City property, the building will be donated to the City and Boreal FC will have use of the building. The City will enter into a use agreement with Boreal FC prior to the building certificate of occupancy. ACTION REQUESTED The Park & Recreation Commission is requested to discuss the proposed Pine Hills North Garage Construction and if acceptable recommend to the City Council to approve the plan contingent to the Building Department plan approval. Attachments: Draft Garage Construction Plans Siding Picture Garage Location Map Construction Cost Estimate Pine Hills North 2013 Master Plan METAL ROOFING 0' - 6" GRADE ALUMINUM FASCIA 4 12 GRADE 1' - 0" ALUMINUM FASCIA ALUMINUM SOFFIT Sc a l e Pr o j e c t n u m b e r Da t e Dr a w n b y Ch e c k e d b y KE S T N E R CO N S T R U C T I O N 1 / 4 " = 1 ' - 0 " 9/ 2 / 2 0 2 6 8 : 2 1 : 5 1 A M A1 . 1 EL E V A T I O N S Pr o j e c t N u m b e r 35 7 2 1 6 1 S T A V E N W AN D O V E R , M N 5 5 3 0 4 09 / 0 2 / 2 0 2 6 SW K Ch e c k e r 1/4" = 1'-0"1 SOUTH ELEVATION 1/4" = 1'-0"2 EAST ELEVATION ROOF TRUSS BRG. 902' - 1 1/8"0' - 6" ROOF TRUSS BRG. 902' - 1 1/8" 1' - 0" SHED FLOOR 892' - 0" SHED FLOOR 892' - 0" METAL ROOFING GRADE ALUMINUM FASCIA 0' - 6" 1' - 0"1' - 0" 4 12 GRADE Sc a l e Pr o j e c t n u m b e r Da t e Dr a w n b y Ch e c k e d b y KE S T N E R CO N S T R U C T I O N 1 / 4 " = 1 ' - 0 " 9/ 2 / 2 0 2 6 8 : 2 1 : 5 1 A M A1 . 2 EL E V A T I O N S Pr o j e c t N u m b e r 35 7 2 1 6 1 S T A V E N W AN D O V E R , M N 5 5 3 0 4 09 / 0 2 / 2 0 2 6 SW K Ch e c k e r 1/4" = 1'-0"1 NORTH ELEVATION 1/4" = 1'-0"2 WEST ELEVATION ROOF TRUSS BRG. 902' - 1 1/8" 0' - 6" SHED FLOOR 892' - 0" ROOF TRUSS BRG. 902' - 1 1/8" SHED FLOOR 892' - 0" 1 A3.1 1 A3.1 3- 0 | 6 - 8 16' - 0" 3' - 0 " 21 ' - 0 " 24 ' - 0 " 16' - 0" 4" CONCRETE SLAB W/ #4 FIBER BAR (2 ) 2 X 8 8' - 0 " X 7 ' - 0 " O V E R H E A D GA R A G E D O O R (2 ) 1 3 / 4 X 9 1 / 4 " L V L 8' CEILING 12 ' - 0 " 12 ' - 0 " Sc a l e Pr o j e c t n u m b e r Da t e Dr a w n b y Ch e c k e d b y KE S T N E R CO N S T R U C T I O N 1 / 4 " = 1 ' - 0 " 9/ 2 / 2 0 2 6 8 : 2 1 : 5 1 A M A2 . 1 FL O O R P L A N Pr o j e c t N u m b e r 35 7 2 1 6 1 S T A V E N W AN D O V E R , M N 5 5 3 0 4 09 / 0 2 / 2 0 2 6 Au t h o r Ch e c k e r 1/4" = 1'-0"1 SHED FLOOR CS-WSP BR A C E D W A L L LI N E 2 - 1 BRACED WALL LINE A-1 CS-WSP BRACED WALL LINE B-1 BR A C E D W A L L LI N E 2 - 1 BRACED WALL LINE B-1 BR A C E D W A L L LI N E 1 - 1 CS - W S P CS - W S P CS - W S P CS - W S P BRACED WALL LINE A-1 CS-WSP 4' - 0"8' - 0" 4' - 0" 16' - 0" 24 ' - 0 " 4' - 0 " 11 ' - 6 " 4 ' - 0 " 4 ' - 6 " 4' - 0 " 16 ' - 0 " 4 ' - 0 " 24 ' - 0 " 4' - 0"8' - 0" 4' - 0" CS-WSP 16' - 0" BR A C E D W A L L LI N E 1 - 1 Sc a l e Pr o j e c t n u m b e r Da t e Dr a w n b y Ch e c k e d b y KE S T N E R CO N S T R U C T I O N 1 / 4 " = 1 ' - 0 " 9/ 2 / 2 0 2 6 8 : 2 1 : 5 1 A M A2 . 2 BR A C E D W A L L P L A N Pr o j e c t N u m b e r 35 7 2 1 6 1 S T A V E N W AN D O V E R , M N 5 5 3 0 4 09 / 0 2 / 2 0 2 6 SW K Ch e c k e r 1/4" = 1'-0"1 BRACED WALL PLAN BRACED WALL NOTES: 1. ALL WALLS DESIGNED PER METHOD CS-WSP OF THE 2020 MN CODE. 2 ALL EXTERIOR WALLS ARE TO BE CONTINUOUSLY SHEATHED WITH A MIN. 3/8" WOOD SHEATHING.3. CONNECTION OF GYPSUM BOARD TO STUDS SHALL BE MIN. 1-7/8" LONG 6D CUP-HEAD NAILS, 6" O.C. AT EDGES & 12" O.C. AT FIELD OF GYPSUM PANEL. 4. STRUCTURAL PANELS (BRACED WALLS) SHALL BE LOCATED AT EACH END & AT LEAST EVERY 25' BETWEEN PANELS. 5. EXTERIOR BRACED WALL LINES SHALL HAVE A BRACED WALL PANEL AT EACH END OF THE BRACED WALL LINE, EXCEPT FOR, 8. (PERPENDICULAR WALL/ROOF) APPLY 2X SOLID BLOCKING BETWEEN ROOF SYSTEM MEMBERS OVER BRACED WALL PANELS W/8D NAILS AT 6" O.C. ALONG LENGTH OF BRACED WALL PANELS WHEN HEEL IS 15.25" OR LESS (FIGURE 3, REFER TO FIG. #4 WHEN OVER 15.25")9. NOTE: NOTES 7 & 8 ABOVE APPLY TO PERPENDICULAR FRAMING, WHEN PARALLEL FLOORS/ROOF SYSTEMS ARE PRESENT, THE FLOOR/ROOF SYSTEM IS TO HAVE BLOCKING MATERIAL ALLOWING FOR NAILING OF BRACED WALL PANEL. INTO SYSTEM ABOVE/BELOW SAID WALL. -BRACED WALL PANELS ARE PERMITTED TO BEGIN NO MORE THAN 10' FROM EACH END OF THEBRACED WALL LINE PROVIDED THAT A 24" PANEL MATCHING TABLE R602.10.7 IS APPLIED-THE END OF EACH BRACED WALL PANEL CLOSEST TO THE CORNERSHALL HAVE A TIE DOWN DEVICEFASTENED TO THE STUD AT THE EDGE OF THE BRACED WALL PANELCLOSEST TO THE CORNER AND TO THE FOUNDATION OR FRAMING BELOW. THE TIE DOWN DEVICE SHALL BE CAPABLE OF PROVIDING AN UPLIFT ALLOWABLE DESIGN VALUE OF AT LEAST 1800 LBS.THE TIE-DOWN DEVICE BE INSTALLED ACCORDANCE WITH THE MANF. RECOMMENDATIONS. 6. INTERIOR BRACED WALL LINES SHALL BE DESIGNED/BUILT PER INTERMITTENT METHOD "GB"-MIN. 1/2" GYPSUM BOARD APPLIED TO EACH SIDE OF 2X4 OR 2X6 STUD WALL@16" O.C. SPACING OF STUDS W/DOUBLETOP PLATE AND SINGLE BTM. -ATTACH GYPSUM TO STUDS W/1-1/4" SCREWS (TYPE W OR S), 7" O.C. AT EDGE & 7" O.C. AT FIELD. 7. (PERPENDICULAR WALL/FLOOR) ALL FLOOR SYSTEMS BETWEEN BRACED WALL PANELS TO HAVE A MIN. 2X4 TOP & BOTTOM BLOCKING BOARD PARALLEL TO BRACED WALL PANELS W?MIN. (3) 16D NAILS. ATTACHING BOTTOM/TOP OF BRACED PANEL PLATE TO FLOOR SYSTEM AT BRACED PANEL WIDTH ONLY. 2X4 BLOCKING TO BE SET BETWEEN FLOOR SYSTEM MEMBERS. SOLID RIM MAY BE USED. WALL PANEL TO STUDS: CONNECTION OF GYPSUM PANEL TO STUDS SHALL BE MIN. 1 -7/8" LONG 6D CUP-HEAD NAIL, 6" O.C. AT EDGES & 12" O.C. AT FIELD OF GYPSUM PANEL. RAFTER OR ROOF TRUSSES TO PLATE, TOE NAIL: MINIMUM (3) 16D BOX NAILS OR (3) 10D COMMON NAILS.(2) TOE NAILS ON ONE SIDE AND (1) TOE NAIL ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS. (MANF. METAL CONNECTORS MAY BE SUBSTITUTED, VERIFYW/MANF. DETAILS). 10 ' - 1 1 / 8 " 4 12 0' - 8 " 1' - 0" ALUMINUM FASCIA ALUMINUM SOFFIT 1/2" OSB ROOF SHEATHING 4" 4,500 CONCRETE SLAB W/ #4 FIBER BAR MANF. ROOF TRUSS 8" THICKENED EDGE 1' - 0"1' - 0" 4" CLASS 5 TREATED 2 X 4 SILL PLATE SET W/SILL SEALER ANCHOR BOLT W/2" X 2" X 3/16" WASHER @4' O.C. MAX SPACING 2 X 4 STUDS @16" O.C. TYP. (2) 2 X 4 TOP PLATE 7/16" OSB WALL SHEATHING AIR BARRIER LAP SIDING Sc a l e Pr o j e c t n u m b e r Da t e Dr a w n b y Ch e c k e d b y KE S T N E R CO N S T R U C T I O N 1 / 4 " = 1 ' - 0 " 9/ 2 / 2 0 2 6 8 : 2 1 : 5 1 A M A3 . 1 BU I L D I N G S E C T I O N S Pr o j e c t N u m b e r 35 7 2 1 6 1 S T A V E N W AN D O V E R , M N 5 5 3 0 4 09 / 0 2 / 2 0 2 6 SW K Ch e c k e r 1/4" = 1'-0"1 SECTION THROUGH SHED METAL ROOFING HIGH TEMP ICE AND WATER SHED FLOOR 892' - 0" ROOF TRUSS BRG. 902' - 1 1/8" Andover General Mapping Sources: Esri, TomTom, Garmin, FAO, NOAA, USGS, © OpenStreetMap contributors, and the GIS User Community Override 1 Override 1 Override 1 Parcel Boundary CityLimits Parcel Boundary AnokaCo_Sp26_6inch_WestCentral.sid Red: Band_1 Green: Band_2 Blue: Band_3 9/10/2026, 10:31:39 AM 0 0.01 0.030.01 mi 0 0.03 0.060.01 km 1:1,644 Disclaimer: Informational use only, not a survey grade accuracy. Storage Shed Estimate Kestner Construction Co 651-442-8148 ryan@kestnerconstruction.com 741 Constance Boulevard Northwest Andover, MN 55304 Residential BLDG Contractor BC746634 Boreal Soccer Club PO Box 43 Elk River, MN 55330 Estimate Number 617 Date Aug 31, 2026 Total:$24,988.00 Quantity Price TotalItem 16’×24’ SHED: Includes class 5, concrete, rebar, all construction materials for standard 8 ft walls with trusses, vinyl siding, aluminum soffit and fascia, metal roofing, 6’x7’ ft roll up door, and a 36" service door. Includes all material, labor, drawings, and permit fees. Material 1 $23,268.00 $23,268.00 Change to a standard garage door 8’wide ×7’ tall Add-on 1 $930.00 $930.00 Change height of 8’ walls to 10’ walls.Includes extra material and labor. Add-on 1 $790.00 $790.00 STAFF REPORT Agenda Item #6 1 TO: Park and Recreation Commission FROM : David D. Berkowitz, Director of Public Works/City Engineer SUBJECT: Discuss 2026 Tree Lighting Event DATE: September 17, 2026 INTRODUCTION The Park and Recreation Commission is requested to discuss the 2026 tree lighting event. BACKGROUND This will be the third year for the tree lighting event, and the plan is to keep it consistent to what was done in 2025. The event is held on the first Friday in December which is December 4th. ACTION REQUESTED The Park & Recreation Commission members are encouraged to provide additional items or activities they would like to see and volunteer to assist in the planning and execution of the event. STAFF REPORT Agenda Item #7 1 TO: Park and Recreation Commission FROM : David D. Berkowitz, Director of Public Works/City Engineer SUBJECT: Outstanding Items DATE: September 17, 2026 Current items as of 09/10/26 UPDATES ON 2026 PARK CIP PROJECTS • Playground Replacements – The equipment for the two 2026 replacements, ASN and Creekview Crossings, have been delivered. Currently looking at September/October installs. • Skatepark Upgrades – Staff is working with American Ramp Company to prepare a draft design/layout that will be put out to the public for comments. City Council has set a total project budget of $400,000 which includes the design and replacement of existing ramps and new concrete feature. Out of this budget $250,000 is coming from the Park Dedication Fund for new improvements. Design and public input will be worked on this fall and winter and construction will begin in the spring of 2027. • Trail Replacement Kelsey Round Lake Park – Construction has begun and will be completed by the end of October. • Bench Additions – Tom Anderson Trail – Benches are on order and should be install late 2026 or early spring 2027. • Sunshine Parking Lot Lighting – The City has contracted with Connexus Energy and the lighting installation will be completed before winter. • Hawkridge Park Parking Lot Paving – Engineering staff has begun working on the design. Construction has been moved out to 2027. • Kelsey Round lake Park Trail Reconstruction – The trail replacement project has begun and it is anticipated work will be completed by the end of September. OTHER ITEMS OF INTEREST • New Trail Segment Along Coon Creek – Construction is completed and staff is working on final paperwork for the MNDNR grant funds. • New Trail Addition – Crosstown Blvd from Xeon to Prairie Rd – The Active Transportation Funding Grant application has been submitted. If you have any questions or comments regarding any of the items mentioned above, or any items relating to parks or projects, feel free to contact David Berkowitz prior to the meeting. Staff recommend the Commission continue reviewing the City Council meeting minutes that you receive by e-mail as to discussions of various projects the City Council has been working on or is considering.